NextGen Para-Tek FR Tri‑Blend Firefighting Hood

30400-02-120083

PGI builds off the winning performance of their Cobra Ultimate hood line to create Cobra NextGen hoods featuring an innovative design that combines exceptional fit, superior performance and unsurpassed comfort. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition.

The Sure Difference:

Cobra Sure‑Fit hoods incorporate a 3" wide center panel rather than the traditional center seam, which allows PGI to contour the hood to the shape of the head for improved fit and comfort. Additionally, Cobra Sure‑Fit hoods have a little extra fabric (ease) built into the design which improves the hood’s thermal resistance from flame and heat due to the extra space adding a layer of air between hood and head and reduces the likelihood of the face opening pulling away from the SCBA mask when head is rotated.

Fabric Description:

PGI's proprietary tri-blend of Lenzing FR®, high strength para-aramid and high tenacity nylon. This superb flame resistant fiber combination offers an outstanding TPP rating, arc flash protection and excellent moisture absorbency.

Sizing:

One size fits most

Options:

Thread
NextGen hoods are available sewn with either color-coordinated (matching) or color-contrasting 100% Nomex® thread.
Embroidered Patches
100% Nomex® embroidered patch. Minimum order 25 each.
Ink Heat Transfers
High resolution multi‑color transfers. Minimum order 100 each.

Features

Test Results

Fabric Performance ValuesRequirements NFPA 1971
2018 Edition
PGI Test Results
Thermal Protective Performance (TPP)
  • As Received
20.0 (min)32.7
  • After 5 Washings
20.0 (min)31.5
Hood Material Burst Strength 225 N476 N
Flame Resistance Test

After Flame (Wales x Courses)

  • As Received
2.0 sec0.0 sec x 0.0 sec
  • After 5 Washings
2.0 sec0.0 sec x 0.0 sec

Char Length (Wales x Courses)

  • As Received
100 mm42 mm x 44 mm
  • After 5 Washings
100 mm28 mm x 41 mm
Cleaning Shrinkage Resistance Test

Hood Measurement

  • After 5 Washings
-5%-0.7%
Heat & Thermal Shrinkage Resistance Test

Hood Measurement

  • As Received
-10%0%
  • After 5 Washings
-10%-0.4%
Limited Oxygen Index (LOI)Not Required31
Seam Breaking Strength Test 181 N789 N
Melt or Drip When Exposed to FlameNo Melting or DrippingNONE
Arc Thermal Performance Value (ATPV)
  • Double Ply
33 cal/cm2
  • Triple Ply
57 cal/cm2
NFPA 70E Hazard Risk Category (HRC)
  • Double Ply
HRC 3
  • Triple Ply
HRC 4

Product Line

Para-Tek FR<sup>™</sup> Tri‑Blend

Para-Tek FR Tri‑Blend

Comfort Plus<sup>™</sup> Nomex<sup>®</sup> (Meta‑Aramid) and Lenzing FR<sup>®</sup>

Comfort Plus Nomex® (Meta‑Aramid) and Lenzing FR®

Carbon Shield<sup>™</sup>

Carbon Shield

PBI/Lenzing FR<sup>®</sup> with Comfort Plus<sup>™</sup> Liner

PBI/Lenzing FR® with Comfort Plus Liner

100% Nomex<sup>®</sup> Meta‑Aramid

100% Nomex® Meta‑Aramid

Ara‑Tek FR<sup>™</sup> Tri‑Blend

Ara‑Tek FR Tri‑Blend